Download this Case Study: Field service engineer discovers excessive damage during routine inspection and executes a difficult on-site repair. Hayward Tyler has supplied High Integrity Gate Valve (HIGV) and ongoing aftermarket support for
Field Service
SRVB #12-Insulation Resistance (IR) measurements for wet stator motors
This service bulletin has been written as a response to questions regarding insulation resistance (IR) and to clarify how to interpret measured values of IR for wet stator motors. There are many factors that influence IR measurements such as
SRVB #11-Preparation and Verification of All Pressure Boundary Flanges on HT Boiler Water Circulating Pumps (BWCP): New Manufacture or Repairs
This Safety Bulletin is in response to customers asking about the suitability of hardware on connection flanges after return from shop service or upon initial receipt of a new motor. The below information serves as guidance about what needs to be
SRVB #8-Boiler Water Circulating Pump-Motor Rotation Verification
This procedure should be viewed as guidance to give the owner advice in verifying that the motor is operating in the correct rotation. It is not a guarantee of the correct rotation, as, at all times, good judgment must be utilized. It is very