Overview & Features of the P100 Series
Ideally suited for remote or difficult-to-access equipment, the P100 Series Portable Condition Monitoring System measures the voltage and current drawn by your equipment’s motor to identify a wide range of specific failure modes and assess damage. It also measures energy consumption and identifies a range of energy wasting parameters.
Testing takes only a few minutes – at the end of which the device creates an automatic written and graphic report that can be edited and emailed.
Simple Installation
The only connections required to operate the P100 series are current clamps to measure the current and dolphin connectors to measure the voltage.
All connections and testing are done in the switch room and are taken from the low voltage and low current signals feeding the protection system. There is no need to disconnect or disturb any existing connections.
Available Outputs
The P100 series Equipment Health Assessment kit provides a wide range of outputs, ranging from basic electrical parameters to advice on corrective action on any faults found. Examples include:
Automated advice depending on fault
Automatic identification of spectral
Automatic identification of rotor bar condition and provision of supporting information
Overview of condition and automatic provision of information on faults detected
Fast, precise reporting
By entering only a few simple parameters, the Health Assessor will rapidly create an automated report of:
- Unbalance/misalignment
- Bearing problems
- Foundation looseness
- Transmission looseness or rubbing
- Motor rotor bar breaks
- Motor stator problems
- Electrical odd harmonic abnormalities
- Electrical even harmonic abnormalities
- Any other spectrum peak beyond the normal expected values
Documents
Download our brochure to read more about Hayward Tyler Condition Monitoring:
Easy, convenient monitoring of the health of your pumps and motors
Watch the video to learn how our Portable Condition Monitoring System works and how it can help you take control of the performance and maintenance of your hard-to-access pumps and motors:
The P100 Series: How can it help you?
- Avoid unnecessary maintenance work
- Avoid unexpected breakdowns by spotting developing
problems before they become critical - Minimize energy wastage and quantify the benefits using
the energy wastage figures - Create a baseline profile of new equipment at a factory
- Perform acceptance and commissioning testing on
equipment to confirm no damage has occurred during
delivery and installation - Monitor the condition of otherwise inaccessible equipment,
such as submerged pumps, borehole pumps, in-tank
pumps, cryogenic pumps, roof mounted fans, etc.
Product Details
Hover over the numbers for details about each feature.
Also included: Power lead + USB cable and PC tablet (not pictured).
Save money with a predictive
maintenance strategy.
A conservative preventative maintenance strategy results in a high cost of maintenance and low cost of failure, while a reactive strategy results in a low cost of maintenance, but a high cost of failure. Our predictive approach reveals the optimal maintenance time to help maximize availability without performing unnecessary maintenance.